๐ ๏ธ Fire & Rescue Service Tools
Explore our collection of free, high-speed browser tools. No ads, no registrations, no server latency.
Filter the 10 tools below, sort them, expand a row for the full description, or keep one in your toolbox with the ๏ผ. Press / to jump to the filter.
-
๐ Drafting & Static Water Supply
Lift, theoretical and dependable lift at your elevation, the intake pressure correction, net pump discharge pressure, and how much of your rated capacity you actually keep at that lift.
-
๐ฅ Fireground Hydraulics โ Friction Loss & Pump Pressure
Friction loss, elevation, appliance loss, pump discharge pressure, solid-stream flow and nozzle reaction for up to five hose sections, with the supply-line hand methods alongside.
-
๐ก๏ธ Firefighter Rehab & WBGT Heat Stress
Wet-bulb globe temperature from your three thermometer readings, the ACGIH screening TLV and action limit for your work/rest cycle, and why the tables stop short of turnout gear.
-
๐ซง Foam Proportioning & Application Rate
Foam solution flow for an area, concentrate per minute and total concentrate for the run time, for Class A and Class B hydrocarbon and polar-solvent spills.
-
๐ช Ground Ladder Placement & Reach
Quarter rule, climbing angle from where the butt actually sits, the height a given ladder reaches, the ladder you need for a given objective, and the collapse zone for the building.
-
โฃ๏ธ Hazmat Concentration Converter
ppm to mg/mยณ and back at the temperature and pressure you are actually working at, ppm to percent by volume, percent LEL to ppm, and what an oxygen reading means.
-
๐ง Hydrant Flow Test & Water Supply
Read your pitot gauge and your two hydrant gauges, and get the percentage method, the first-digit method, the available fire flow at 20 psi residual, and whether the test is even valid.
-
๐ Required Fire Flow Calculator
Needed fire flow by the National Fire Academy, Iowa State and ISO methods side by side, with exposure charges and a hoseline plan for the answer.
-
๐ซ SCBA Air Management & Turnaround Pressure
Rule of thirds, EOSTI activation pressure, the actual duration your cylinder will last at a real consumption rate, and how long your air has been going based on how much you have used.
-
๐ Tanker Shuttle Delivery Rate
How many gallons per minute a water tender shuttle can actually put on the fire โ NFPA 1142 cycle time, the 10 % unusable capacity allowance, and how many tenders you need for the flow you want.
Looking for something else? Filter all 1250 tools โ