🔌 Halloween Decoration Power Budget
🔌 Halloween Decoration Power Budget
Add up every prop on the circuit, check the breaker and the extension lead, and see what the display costs to run each night.
Voltage drop along the lead against length for four cable sizes at your current. The dashed line is the 5% limit.
Load report
—
More Halloween tools: fog machine calculator · haunted house throughput · party games · the Halloween guide
How the load, the cable and the cost are calculated
The load. Every appliance's rated wattage is added and scaled by the proportion running at once. That matters: a fog machine cycles its heater, while a projector and a blower run continuously. Add up the labels, then be honest about which ones are on together — Christmas and Halloween displays usually trip a breaker in the first hour of the first cold night.
Current and headroom. Current is watts divided by volts. A 13 A socket is not a 13 A target: continuous loads are normally kept to about 80% of the breaker or socket rating, so the planner shows the headroom that remains and flags anything above it. The existing load on the circuit matters too — the decorations share the ring main with whatever else is plugged in.
Voltage drop. For a copper lead, drop ≈ 2 × length × current × 0.0175 ÷ cross-section, with length in metres and cross-section in mm². The factor of two accounts for the out-and-back path. A 20 m, 1.5 mm² lead carrying 7 A loses about 3.3 V, or 1.4%, which is fine; a 40 m, 0.75 mm² lead carrying the same current loses over 13 V and gets warm. Above about 5% the props dim and motors strain; the cable's current rating matters more than the drop.
Cost. Energy is kilowatts × hours. Multiply by the nights on display and the tariff on your bill (the default is a recent UK-style figure, not a promise). The biggest saving is usually the blower left running after the last visitor, not a new set of bulbs.
Last reviewed: 2026-10-20. A planning estimate, not an electrical installation design. Use RCD-protected outdoor sockets, keep connections out of standing water, and follow local wiring rules.